Product summary | Standard size for general-purpose induction motors |
---|---|
Product purpose | Control the electricity to a motor starting coil |
Intended use | Split-phase starting of a single-phase motor |
Operating type | This product consists of a fixed part and a rotating part, and is mounted in the thrust direction of a motor shaft. It turns a contact on/off at certain rotational speeds. |
Compatible standard | RoHS compliant |
Outer dimensions | Rotating part: φ52 × 32.5 |
---|---|
Case material | Frictional part, bottom plate: phenol |
Operating temperature range | -10~80℃ |
Product mounting method | Mounting shaft diameter |
Rated voltage | AC 125V/250V |
---|---|
Rated capacity | 250W~7.5kW |
Contact withstand current | Inrush current: 30 A or less |
Contact withstand count | 250,000 or more (no load) |
Withstand voltage | 1500 VAC for 1 minute or 1800 VAC for 1 second |
Insulation resistance | 500 VDC megohmmeter |
Product summary | Standard size for general-purpose induction motors |
---|---|
Product purpose | Control the electricity to a motor starting coil |
Intended use | Split-phase starting of a single-phase motor |
Operating type | This product consists of a fixed part and a rotating part, and is mounted in the thrust direction of a motor shaft. |
Compatible standard | RoHS compliant |
Outer dimensions | Rotating part: φ52 × 23 |
---|---|
Case material | Frictional part, bottom plate: phenol |
Operating temperature range | -10~80℃ |
Product mounting method | Mounting shaft diameter |
Rated voltage | AC 125V/250V |
---|---|
Rated capacity | 250W~400W |
Contact withstand current | 250 W: 10 A or less |
Contact withstand count | 500,000 or more (no load) |
Withstand voltage | 1500 VAC for 1 minute or 1800 VAC for 1 second |
Insulation resistance | 500 VDC megohmmeter |