Product
产品信息
产品信息
Product summary | Turns a pump on and off (for household use) |
---|---|
Product purpose | Detect a pump's discharge pressure and automatically start/stop it |
Intended use | Detect a pump's discharge pressure |
Operating type | Consists of a pressure-receiving area, contact circuit area, switch quick-operating mechanism, and pressure adjustment mechanism |
Compatible standard | RoHS compliant |
Outer dimensions | Φ 53×83 |
---|---|
Case material | Cover: ABS |
Operating temperature range | -20~80℃ |
Connection terminal type | G3/8 (PF3/8) female screw |
Product mounting method | Pressure: Insert the seal into the G3/8 (PF3/8) female screw, and tighten it to a male screw |
Rated voltage | AC 125/250V |
---|---|
Rated capacity | 400/750W |
Contact withstand count | 1 million times |
Withstand voltage | 1500 VAC for 1 minute or 1800 VAC for 1 second |
Insulation resistance | 500 VDC megohmmeter 10 MΩ or higher |
Product summary | Turns a pump on and off (for household use) |
---|---|
Product purpose | Detect a pump's discharge pressure and automatically start/stop it |
Intended use | Detect a pump's discharge pressure |
Operating type | Consists of a pressure-receiving area, contact circuit area, switch quick-operating mechanism, and pressure adjustment mechanism |
Compatible standard | Electrical Appliances and Materials Safety Act RoHS compliant |
Outer dimensions | Φ 53×83 |
---|---|
Case material | Cover: ABS |
Operating temperature range | -20~80℃ |
Connection terminal type | R,G1/4(PT,PF1/4) R,G3/8(PT,PF3/8) female screws |
Product mounting method | Pressure: Tighten the above female screw into a male screw |
Rated voltage | AC 125/250V |
---|---|
Rated capacity | 400/750W |
Contact withstand current | Rush 16.7 A / Breaking 6 A |
Contact withstand count | 1 million times |
Withstand voltage | 1500 VAC for 1 minute or 1800 VAC for 1 second |
Insulation resistance | 500 VDC megohmmeter 10 MΩ or higher |
Product summary | Turns a pump on and off (for water tank) |
---|---|
Product purpose | Detect a pump's discharge pressure and automatically start/stop it |
Intended use | Detect a pump's discharge pressure, and pressure inside a water tank |
Operating type | Consists of a pressure-receiving area, contact circuit area, switch quick-operating mechanism, and pressure adjustment mechanism |
Compatible standard | Electrical Appliances and Materials Safety Act RoHS compliant |
Outer dimensions | 67×95×185 |
---|---|
Case material | Cover, case: iron |
Operating temperature range | 0~80℃ |
Connection terminal type | R3/8 (PT3/8) male screw |
Product mounting method | Pressure: Tighten the R3/8 (PT3/8) male screw into a female screw |
Rated voltage | AC 125/250V |
---|---|
Rated capacity | 400/750W |
Contact withstand count | 1 million times |
Withstand voltage | 1500 VAC for 1 minute or 1800 VAC for 1 second |
Insulation resistance | 500 VDC megohmmeter 10 MΩ or higher |