Product
产品信息
产品信息
Product summary | Detects overcurrent / locked rotor current and protects a motor from burnout |
---|---|
Product purpose | Prevent compressor motor burnout |
Intended use | Compressor (for refrigerators, air conditioners, and other appliances) |
Operating type | Bimetal type |
Compatible standard | UL、VDE、CQC |
Case material | Phenolic resin |
---|---|
Operating temperature range | Temperature near motor: 20°C to 100°C |
Connection terminal type | Solder terminal |
Product mounting method | Place the product into a Φ25 hole and bring it into intimate contact with the motor |
Rated voltage | AC 125/250V |
---|---|
Rated capacity | Up to 1.5 kW |
Contact withstand current | 60/40A |
Contact withstand count | 10,000 times or more |
Withstand voltage | 1500 V for 1 minute |
Insulation resistance | 100 MΩ or higher with a 500-VDC megohmmeter |
Product summary | Detects overcurrent / locked rotor current and protects a motor from burnout |
---|---|
Product purpose | Prevent compressor motor burnout |
Intended use | Compressor (for refrigerators, air conditioners, and other appliances) |
Operating type | Bimetal type |
Compatible standard | UL、VDE、CQC |
Case material | Unsaturated polyester |
---|---|
Operating temperature range | Temperature near motor: 20°C to 100°C |
Connection terminal type | FASTON tab terminal (#250) |
Product mounting method | Place the product into a Φ25 hole and bring it into intimate contact with the motor |
Rated voltage | AC 125/250V |
---|---|
Rated capacity | Up to 1.5 kW |
Contact withstand current | 60/40A |
Contact withstand count | 10,000 times or more |
Withstand voltage | 1500 V for 1 minute |
Insulation resistance | 100 MΩ or higher with a 500-VDC megohmmeter |
Product summary | Detects overcurrent / locked rotor current and protects a motor from burnout |
---|---|
Product purpose | Prevent burnout of general-purpose three-phase motors |
Intended use | Submerged pump |
Operating type | Bimetal type (Convert a current applied to the product into heat in the internal heater, which then operates the bimetal and interrupts the circuit) |
Compatible standard | UL |
Case material | Phenolic resin |
---|---|
Operating temperature range | Temperature near motor: 20°C to 100°C |
Connection terminal type | Solder incurved terminal |
Product mounting method | Fixed in place with M4 screws or by other means |
Rated voltage | AC 250/500V |
---|---|
Rated capacity | Up to 1.0 kW |
Contact withstand current | 30/20A |
Contact withstand count | 5,000 times or more |
Withstand voltage | 1500 V for 1 minute |
Insulation resistance | 50 MΩ or higher with a 500-VDC megohmmeter |
Product summary | Detects overcurrent / locked rotor current and protects a motor from burnout |
---|---|
Product purpose | Prevent burnout of general-purpose three-phase motors |
Intended use | Submerged pump |
Operating type | Bimetal type (Convert a current applied to the product into heat in the internal heater, which then operates the bimetal and interrupts the circuit) |
Compatible standard | UL (with some exceptions) |
Case material | Phenolic resin |
---|---|
Operating temperature range | Temperature near motor: 20°C to 100°C |
Connection terminal type | Solder incurved terminal |
Product mounting method | Fixed in place with M4 screws or by other means |
Rated voltage | AC 250/500V |
---|---|
Rated capacity | Up to 2.2 kW |
Contact withstand current | 80/50A |
Contact withstand count | 3,000 times or more |
Withstand voltage | 1500 V for 1 minute |
Insulation resistance | 50 MΩ or higher with a 500-VDC megohmmeter |
Product summary | Detects overcurrent / locked rotor current and protects a motor from burnout |
---|---|
Product purpose | Prevent burnout of general-purpose three-phase motors |
Intended use | Submerged pump |
Operating type | Bimetal type (Convert a current applied to the product into heat in the internal heater, which then operates the bimetal and interrupts the circuit) |
Compatible standard | UL (with some exceptions) |
Case material | Phenolic resin |
---|---|
Operating temperature range | Temperature near motor: 20°C to 100°C |
Connection terminal type | Solder incurved terminal |
Product mounting method | Fixed in place with M4 screws or by other means |
Rated voltage | AC 250/500V |
---|---|
Rated capacity | Up to 7.5 kW |
Contact withstand current | 200/150A |
Contact withstand count | 2,000 times or more |
Withstand voltage | 1500 V for 1 minute |
Insulation resistance | 50 MΩ or higher with a 500-VDC megohmmeter |
Product summary | Detects overcurrent / locked rotor current and protects a motor from burnout |
---|---|
Product purpose | Prevent burnout of general-purpose three-phase motors |
Intended use | Submerged pump |
Operating type | Bimetal type (Convert a current applied to the product into heat in the internal heater, which then operates the bimetal and interrupts the circuit) |
Compatible standard | UL (with some exceptions) |
Case material | Phenolic resin |
---|---|
Operating temperature range | Temperature near motor: 20°C to 100°C |
Connection terminal type | Solder incurved terminal |
Product mounting method | Fixed in place with M4 screws or by other means |
Rated voltage | AC 250/500V |
---|---|
Rated capacity | Up to 15 kW |
Contact withstand current | 300/200A |
Contact withstand count | 1,000 times or more |
Withstand voltage | 1500 V for 1 minute |
Insulation resistance | 50 MΩ or higher with a 500-VDC megohmmeter |
Product summary | Detects overcurrent / locked rotor current and protects a motor from burnout |
---|---|
Product purpose | Prevent burnout of general-purpose three-phase motors |
Intended use | Submerged pump |
Operating type | Bimetal type (Convert a current applied to the product into heat in the internal heater, which then operates the bimetal and interrupts the circuit) |
Compatible standard | UL (with some exceptions) |
Case material | Phenolic resin |
---|---|
Operating temperature range | Temperature near motor: 20°C to 100°C |
Connection terminal type | Thread-fastening terminal |
Product mounting method | Fixed in place with M5 screws or by other means |
Rated voltage | AC 250/500V |
---|---|
Rated capacity | Up to 37 kW |
Contact withstand current | 600/400A |
Contact withstand count | 1,000 times or more |
Withstand voltage | 1500 V for 1 minute |
Insulation resistance | 50 MΩ or higher with a 500-VDC megohmmeter |
Product summary | Detects overcurrent / locked rotor current and protects a motor from burnout |
---|---|
Product purpose | Prevent burnout of general-purpose motors |
Intended use | Electric power tools, food shredders, and other electric appliances that must not be automatically returned |
Operating type | Bimetal type |
Compatible standard | None |
Case material | Phenolic resin |
---|---|
Operating temperature range | Temperature near motor: 20°C to 100°C |
Connection terminal type | Terminal with holes |
Product mounting method | Place the product into a Φ25 hole and press it down on an item you want to protect |
Rated voltage | AC 125/250V |
---|---|
Rated capacity | Up to 1.5 kW |
Contact withstand current | 60/40A |
Contact withstand count | 200 times or more |
Withstand voltage | 1500 V for 1 minute |
Insulation resistance | 50 MΩ or higher with a 500-VDC megohmmeter |
Product summary | Detects overcurrent / locked rotor current and protects a motor from burnout |
---|---|
Product purpose | Prevent compressor motor burnout |
Intended use | Compressor motor of refrigerators and other appliances |
Operating type | Bimetal type |
Compatible standard | None |
Case material | Unsaturated polyester + PBT resin |
---|---|
Operating temperature range | Temperature near motor: 20°C to 100°C |
Connection terminal type | Terminal for hermetic pin |
Product mounting method | Insert into a common terminal of a compressor's hermetic pin |
Rated voltage | AC 125/250V |
---|---|
Rated capacity | Up to 0.8 kW |
Contact withstand current | 20/15A |
Contact withstand count | 10,000 times or more |
Withstand voltage | 1500 V for 1 minute |
Insulation resistance | 100 MΩ or higher with a 500-VDC megohmmeter |
Product summary | Detects overcurrent / locked rotor current and protects a motor from burnout |
---|---|
Product purpose | Prevent burnout of general-purpose three-phase motors |
Intended use | Various industrial motors |
Operating type | Bimetal type |
Compatible standard | None |
Case material | Phenolic resin |
---|---|
Operating temperature range | Temperature near motor: 20°C to 100°C |
Connection terminal type | Solder incurved terminal |
Product mounting method | Fixed in place with M4 screws or by other means |
Rated voltage | AC 250/500V |
---|---|
Rated capacity | Up to 1.0 kW |
Contact withstand current | 30/20A |
Contact withstand count | 200 times or more |
Withstand voltage | 1500 V for 1 minute |
Insulation resistance | 50 MΩ or higher with a 500-VDC megohmmeter |
Product summary | Detects overcurrent / locked rotor current and protects a motor from burnout |
---|---|
Product purpose | Prevent burnout of general-purpose three-phase motors |
Intended use | Various industrial motors |
Operating type | Bimetal type |
Compatible standard | None |
Case material | Phenolic resin |
---|---|
Operating temperature range | Temperature near motor: 20°C to 100°C |
Connection terminal type | Solder incurved terminal |
Product mounting method | Fixed in place with M4 screws or by other means |
Rated voltage | AC 250/500V |
---|---|
Rated capacity | Up to 2.2 kW |
Contact withstand current | 80/50A |
Contact withstand count | 200 times or more |
Withstand voltage | 1500 V for 1 minute |
Insulation resistance | 50 MΩ or higher with a 500-VDC megohmmeter |
Product summary | Detects overcurrent / locked rotor current and protects a motor from burnout |
---|---|
Product purpose | Prevent burnout of general-purpose motors |
Intended use | Electric power tools, food shredders, and other electric appliances that must not be automatically returned |
Operating type | Bimetal type |
Compatible standard | None |
Case material | Phenolic resin |
---|---|
Operating temperature range | Temperature near motor: 20°C to 100°C |
Connection terminal type | Terminal with holes |
Product mounting method | Place the product into a Φ30 hole and press it down on an item you want to protect |
Rated voltage | AC 125/250V |
---|---|
Rated capacity | Up to 2.2 kW |
Contact withstand current | 80/50A |
Contact withstand count | 200 times or more |
Withstand voltage | 1500 V for 1 minute |
Insulation resistance | 50 MΩ or higher with a 500-VDC megohmmeter |
Product summary | Detects overcurrent / locked rotor current and protects a motor from burnout |
---|---|
Product purpose | Prevent burnout of general-purpose single-phase motors |
Intended use | Electric power tools, food shredders, and other electric appliances that must not be automatically returned |
Operating type | Bimetal type |
Compatible standard | None |
Case material | Phenolic resin |
---|---|
Operating temperature range | Temperature near motor: 20°C to 100°C |
Connection terminal type | Terminal with holes |
Product mounting method | Fixed in place with M4 screws or by other means |
Rated voltage | AC 125/250V |
---|---|
Rated capacity | Up to 1.5 kW |
Contact withstand current | 60/40A |
Contact withstand count | 200 times or more |
Withstand voltage | 1500 V for 1 minute |
Insulation resistance | 50 MΩ or higher with a 500-VDC megohmmeter |
Product summary | Detects overcurrent / locked rotor current and protects a motor from burnout |
---|---|
Product purpose | Prevent burnout of general-purpose single-phase motors |
Intended use | Electric power tools, food shredders, and other electric appliances that must not be automatically returned |
Operating type | Bimetal type |
Compatible standard | None |
Case material | Phenolic resin |
---|---|
Operating temperature range | Temperature near motor: 20°C to 100°C |
Connection terminal type | Terminal with holes |
Product mounting method | Fixed in place with M4 screws or by other means |
Rated voltage | AC 125/250V |
---|---|
Rated capacity | Up to 2.2 kW |
Contact withstand current | 80/50A |
Contact withstand count | 200 times or more |
Withstand voltage | 1500 V for 1 minute |
Insulation resistance | 50 MΩ or higher with a 500-VDC megohmmeter |
Product summary | Detects overcurrent / locked rotor current and protects a motor from burnout |
---|---|
Product purpose | Prevent burnout of general-purpose single-phase motors |
Intended use | Submerged pump |
Operating type | Bimetal type |
Compatible standard | UL |
Case material | Phenolic resin |
---|---|
Operating temperature range | Temperature near motor: 20°C to 100°C |
Connection terminal type | Solder terminal |
Product mounting method | Fixed in place with M4 screws or by other means |
Rated voltage | AC 125/250V |
---|---|
Rated capacity | Up to 1.5 kW |
Contact withstand current | 60/40A |
Contact withstand count | 5,000 times or more |
Withstand voltage | 1500 V for 1 minute |
Insulation resistance | 50 MΩ or higher with a 500-VDC megohmmeter |
Product summary | Detects overcurrent / locked rotor current and protects a motor from burnout |
---|---|
Product purpose | Prevent burnout of general-purpose single-phase motors |
Intended use | Submerged pump |
Operating type | Bimetal type |
Compatible standard | UL (with some exceptions) |
Case material | Phenolic resin |
---|---|
Operating temperature range | Temperature near motor: 20°C to 100°C |
Connection terminal type | Solder terminal |
Product mounting method | Fixed in place with M4 screws or by other means |
Rated voltage | AC 125/250V |
---|---|
Rated capacity | Up to 2.2 kW |
Contact withstand current | 80/50A |
Contact withstand count | 2,000 times or more |
Withstand voltage | 1500 V for 1 minute |
Insulation resistance | 50 MΩ or higher with a 500-VDC megohmmeter |
Product summary | Detects overcurrent / locked rotor current and protects a motor from burnout |
---|---|
Product purpose | Prevent burnout of general-purpose single-phase motors |
Intended use | Submerged pump |
Operating type | Bimetal type |
Compatible standard | UL |
Case material | Phenolic resin |
---|---|
Operating temperature range | Temperature near motor: 20°C to 100°C |
Connection terminal type | Solder terminal |
Product mounting method | Fixed in place with M4 screws or by other means |
Rated voltage | AC 125/250V |
---|---|
Rated capacity | Up to 7.5 kW |
Contact withstand current | 200/150A |
Contact withstand count | 2,000 times or more |
Withstand voltage | 1500 V for 1 minute |
Insulation resistance | 50 MΩ or higher with a 500-VDC megohmmeter |
Product summary | Detects overcurrent / locked rotor current and protects a motor from burnout |
---|---|
Product purpose | Prevent compressor motor burnout |
Intended use | Compressor (for refrigerators, air conditioners, and other appliances) |
Operating type | Bimetal type |
Compatible standard | UL |
Case material | Phenolic resin |
---|---|
Operating temperature range | Temperature near motor: 20°C to 100°C |
Connection terminal type | Solder terminal |
Product mounting method | Place the product into a Φ30 hole and bring it into intimate contact with the motor |
Electrical Characteristics | AC 125/250V |
---|---|
Rated capacity | Up to 2.2 kW |
Contact withstand current | 80/50A |
Contact withstand count | 3,000 times or more |
Withstand voltage | 1500 V for 1 minute |
Insulation resistance | 100 MΩ or higher with a 500-VDC megohmmeter |
Product summary | In addition to the features of the 122 model, this product has an independent temperature protection feature. |
---|---|
Product purpose | Prevent compressor motor burnout |
Intended use | Compressor (for refrigerators, air conditioners, and other appliances) |
Operating type | Bimetal type |
Compatible standard | UL、VDE |
Mechanical Characteristics | Phenolic resin (unsaturated polyester) |
---|---|
Operating temperature range | Temperature near motor: 20°C to 100°C |
Connection terminal type | Solder terminal |
Product mounting method | Same as KA-122 |
Rated voltage | AC 125/250V |
---|---|
Rated capacity | Up to 1.5 kW |
Contact withstand current | 60/40A |
Contact withstand count | 5,000 times or more |
Withstand voltage | 1500 V for 1 minute |
Insulation resistance | 100 MΩ or higher with a 500-VDC megohmmeter |